COMMERCIAL BUILDINGS
GENERAL DESIGN REQUIREMENTS SECTION 1604
WIND LOAD Table 1604.5 and Section 1609
ROOF LIVE LOAD REF. IBC TABLE 1607.1
SNOW LOAD Section 1608, ASCE 7
SEISMIC LOADS IBC 1613
FROST LINE 13 INCHES
SOIL TERMITE PROTECTION IS REQUIRED
THIS AREA IS SUBJECT TO DECAY AND WEATHERING - MODERATE
RESIDENTIAL BUILDINGS
REFERENCE IRC R-301.2(1)
SEISMIC DESIGN CATEGORY - D1
ROOF LIVE LOAD Table R301.6
GROUND SNOW LOAD 10 LBS. PSF Figure R301.2(5)
WIND SPEED 115 MPH Figure R301.2(4) A
FROST LINE DEPTH 13 INCHES
WINTER DESIGN TEMP 18
ICE BARRIER UNDERLAYMENT REQUIRED NO
AIR FREEZING INDEX 382
MEAN ANNUAL TEMP 59.2
TERMITE PROTECTION REQUIRED YES
THIS AREA IS SUBJECT TO DECAY AND WEATHERING - MODERATE
EXTERIOR WALL INSULATION: R-13
ATTIC INSULATION: R-38
WINDOWS: SOLAR 0.25 U-FACTOR 0.35